﻿Changehistory file
------------------------------------------------------------------------

Products: MVK Pro MEC DIO8 IOL8 M12L 5P (54612) and IMPACT67 Pro EC DIO8 IOL8 M12L 5P (54632)
Name:     Murrelektronik_MVK-IMPACT67_Pro.xml and Murrelektronik_MVK-IMPACT67_Pro_Diag.xml
Date:     2023-04-30

CHANGE NOTES
============

2024-04-30
------------------------------------------------------------------------
- Tag hinzugefügt:
				
<IdentificationAdo>#x0012</IdentificationAdo>
				

2024-01-26
------------------------------------------------------------------------
- Offline-Wert für "Manufacturer Software Version" auf "V1.7.1" gesetzt.
- Tag hinzugefügt:
				<Info>
					<IdentificationReg134>1</IdentificationReg134>
				</Info>
- EoE-Parameter IP auf den Wert "0" geändert.

2023-11-02
------------------------------------------------------------------------
- "Static on" für Pin 4 deaktiviert, umbenannt und aus Startup entfernt.

2023-10-31
------------------------------------------------------------------------
- Offline-Wert für "Manufacturer Software Version" auf "V1.7.0" gesetzt.

2023-09-25
------------------------------------------------------------------------
- Byte Swap mit Wert 0 in die StartUp-Transitions aufgenommen
- BitSize von DT21x0 von 72 auf 64 korrigiert
- Offline-Wert für "Manufacturer Software Version" nun auch in der CTT auf "V1.6.0" gesetzt.

2023-05-17
------------------------------------------------------------------------
- neue Diagnosen verfügbar (#55598)

2023-05-05
------------------------------------------------------------------------
- Index 6100 durch 2200 ersetzt (#49953)
- Kommentar-Text korrigiert (#55627)
- Diagnose-Texte teilweise nicht in deutsch vorhanden

2023-02-01
------------------------------------------------------------------------
- diagnostic messages: english and german language support
- update of offline data (VendorID, Manufacturer Device Name,...)
- neuer Index 2100.6 Swap
- neuer Index 6100 ISDU over CAN

2022-10-11  54612_MVK_PRO_KF4_x_16.zip
------------------------------------------------------------------------
- Change of default CQ/IQ input filter time to 0 = no filter (ticket #51623)
- Default module changed to "Empty Slot" to be aligned with new remanent data handling in case of Factory Reset
- Text changed: "Pin CQ" -> "Pin 4 (CQ)"
- Text changed: "Pin IQ" -> "Pin 2 (IQ)"
- Text changed: "11" -> "0x11" in Text for data storage plausibility check


2022-07-29  54612_MVK_PRO_KF4_x_15.zip
------------------------------------------------------------------------
- certified ESI file added
- neu folder structure

2022-07-04  54612_MVK_PRO_KF4_x_14.zip
------------------------------------------------------------------------
- Correction of output data description

2022-05-04  54612_MVK_PRO_KF4_x_13.zip
------------------------------------------------------------------------
- IOLM files added

2022-03-22  54612_MVK_PRO_KF4_x_12.zip
------------------------------------------------------------------------
- Merge of ESI files of 54612 and 54632 to one file

2022-03-02  54612_MVK_PRO_KF4_x_11.zip
------------------------------------------------------------------------
- EEProm size changed to 65536

2022-02-07  54612_MVK_PRO_KF4_x_10.zip
------------------------------------------------------------------------
- Initial version